VSEn/Add DASD: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 8: | Line 8: | ||
// EXEC ICKDSF,SIZE=AUTO | // EXEC ICKDSF,SIZE=AUTO | ||
INIT UNIT(202) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR000) | INIT UNIT(202) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR000) | ||
U | |||
INIT UNIT(203) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR001) | INIT UNIT(203) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR001) | ||
U | |||
/* | /* | ||
/& | /& | ||
Make sure to `ONLINE` the DASD first on the console. |
Revision as of 12:26, 17 March 2023
To add DASD, you need to have it available on your FC SAN and have available FCP devices. Then, in the define device screen, add a device, specify FBA SCSI and use the menus to provide the LUN and target WWN. Once this is done, reIPL.
Afterwards, you need to plot down a VTOC and init the DASD using ICKDSF. The following JCL template helps:
// JOB NEWDASD // EXEC ICKDSF,SIZE=AUTO INIT UNIT(202) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR000) U INIT UNIT(203) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR001) U /* /&
Make sure to `ONLINE` the DASD first on the console.