VSEn/Add DASD: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 4: | Line 4: | ||
Afterwards, you need to plot down a VTOC and init the DASD using ICKDSF. The following JCL template helps: | Afterwards, you need to plot down a VTOC and init the DASD using ICKDSF. The following JCL template helps: | ||
// JOB INIT160 | // JOB INIT160 | ||
// EXEC ICKDSF,SIZE=AUTO | |||
// EXEC ICKDSF,SIZE=AUTO | INIT UNIT(202) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR000) | ||
INIT UNIT(203) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR001) | |||
/* | /* | ||
/& | /& | ||
Revision as of 12:24, 17 March 2023
To add DASD, you need to have it available on your FC SAN and have available FCP devices. Then, in the define device screen, add a device, specify FBA SCSI and use the menus to provide the LUN and target WWN. Once this is done, reIPL.
Afterwards, you need to plot down a VTOC and init the DASD using ICKDSF. The following JCL template helps:
// JOB INIT160 // EXEC ICKDSF,SIZE=AUTO INIT UNIT(202) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR000) INIT UNIT(203) NOVFY FBAVTOC(306176,228,8192) VOLID(CBR001) /* /&